Ureteral Dilators & Sets

Ureteral Dilators & Sets

Single dilators 6, 8, 10, 12, 14, 16, 18, 20 Fr
Standard length 70 cm
Set configurations 6–16, 6–18, 10–18, 6–14, 6–10, 8–16, 6–12 Fr
Zirve portfolio target 3–30 Fr; 5–500 cm

Purpose / Clinical Use

Used for dilation of the ureter prior to ureteroscopy and stone manipulation, providing a working channel for introduction of a ureteroscope and other devices.

Key Features

  • Optimal radiopacity for visualization.
  • Long tapered tip supports atraumatic entry and can reduce the need for repeated dilation.
  • Smooth surface for controlled introduction.
  • Hydrophilic- coated versions may be offered where specified.
Fascial Dilators & Sets

Fascial Dilators & Sets

Single dilators 6, 8, 10, 12, 14, 16, 18, 20 Fr
Standard length 22 cm
Set examples 6–16, 6–10, 8–14 Fr
Zirve portfolio target 3–30 Fr; 5–500 cm

Purpose / Clinical Use

Fascial dilator sets are used to create and progressively enlarge a tract for nephrostomy catheter access, with graduated sizes intended to support controlled dilation.

Key Features

  • Radiopaque polymer construction for procedural visualization.
  • Smooth surface assists guidewire- based introduction.
  • Used before nephroscopy and for stone- management access.
  • Hydrophilic- coated versions may be available.
Nottingham One-Step Dilator

Nottingham One-Step Dilator

Configurations 5/10, 6/10, 6/12, 7/12, 7/14, 7/16, 7/18 Fr
Standard length 70 cm
Zirve portfolio target 3–30 Fr; 5–500 cm

Purpose / Clinical Use

Designed to dilate the intramural tunnel and ureter in one step. Used for contrast injection to assess submucosal tunnelling or for anaesthetic jelly during stone dislodgement.

Key Features

  • Radiopaque for visualization.
  • Long tapered tip designed to avoid sequential dilation.
  • Smooth surface for atraumatic entry.
  • Hydrophilic and non- hydrophilic configurations may be considered.
Renal Dilator with Amplatz Sheath

Renal Dilator with Amplatz Sheath

Renal dilator sizes 12–30 Fr
Renal dilator length 30 cm
Amplatz sheath OD 28, 30, 32, 34 Fr; 17 cm
Set code ARD SETS
Set components Fascial dilator 6–10 Fr / 22 cm; renal dilator 12–30 Fr / 30 cm; Amplatz sheath 28–34 Fr / 17 cm; 8 Fr guiding catheter; 10 Fr radiopaque dilation sheath

Purpose / Clinical Use

Designed for dilation of the percutaneous tract and establishment of a working channel into the kidney during PCNL using an Amplatz sheath.

Key Features

  • Gradual tapered tip for placement and maneuverability.
  • Smooth surface for controlled dilation.
  • Radiopaque design for visualization.
  • Set configuration can combine fascial dilators, renal dilators, sheath, guiding catheter and radiopaque dilation sheath.
S-Shaped Urethral Dilator

S-Shaped Urethral Dilator

Set 8, 10, 12, 14, 16, 18, 20, 22 Fr
length 37 cm
Guidewire 0.038 in configuration

Purpose / Clinical Use

An S- shaped urethral dilator configuration is intended to follow the natural curvature of the male urethra during dilation. Contains an S- shape urethral dilator set; external clinical literature specifically describes S- shaped coaxial dilators inserted over a guidewire.

Key Features

  • S- shaped geometry follows the male urethral curvature.
  • Smooth surface for easier introduction.
  • Side hole can be provided for drainage in the design.
  • Hydrophilic coating may be offered.
Urethral Dilator

Urethral Dilator

Configurations 8/6, 10/6, 12/7, 14/7, 16/8, 18/8, 20/8, 22/8 Fr
Standard length 40 cm
Form Filiform / tapered configuration
Zirve portfolio target 3-30 Fr, 5-500 cm

Purpose / Clinical Use

Intended to dilate urethral strictures, negotiate the true path of the urethral lumen and provide access toward the bladder.

Key Features

  • Radiopaque for visualization.
  • Long tapered tip for controlled advancement.
  • Smooth surface for atraumatic entry.
  • Hydrophilic and non- hydrophilic configurations may be considered.
Access Sheath with Dilators

Access Sheath with Dilators

Reference configurations Ureteral access sheath systems commonly specify inner diameter, outer diameter and length
Example external range Inner 9.5–12 Fr; outer 11.5–14 Fr; lengths 28–45 cm in one reference product family
Zirve portfolio target 3–30 Fr; 5–500 cm
Variants Straight or bendable configurations may be developed where clinically appropriate

Purpose / Clinical Use

An access sheath with dilator establishes a conduit for passage of endoscopes or other instruments during endoscopic urological procedures. The tapered dilator helps introduce the sheath over a guidewire.

Key Features

  • Tapered dilator tip for smooth insertion and ureteral dilation.
  • Hydrophilic coating may reduce insertion friction.
  • Radiopaque markers can support fluoroscopic positioning.
  • Sheath and dilator can be supplied as a matched system.
Meatal Dilator

Meatal Dilator

Male configuration MD6/16
Female configuration MDF
Pediatric configuration MDF
Zirve portfolio target 3–30 Fr; 5–500 cm
Configuration Single

Purpose / Clinical Use

Used for dilation of the penile urethral meatus. The supplied also notes that a female meatal dilator configuration may be available.

Key Features

  • Simple, controlled dilation geometry.
  • Male and female configurations can be offered.
  • Smooth surface intended for controlled introduction.
  • Final size progression and material to be specified by Zirve.
Urethral Dilators & Sets

Urethral Dilators & Sets

Single sizes 6, 8, 10, 12, 14, 16, 18, 20, 22, 24 Fr
Standard length 40 cm
Set examples 8–16; 6–18; 10–18 Fr
Zirve portfolio target 3–30 Fr; 5–500 cm

Purpose / Clinical Use

Used to dilate urethral strictures and establish or maintain bladder access through the urethra for cystoscopy.

Key Features

  • Radiopaque for visualization.
  • Smooth surface for atraumatic entry.
  • Side hole available for drainage in the configuration.
  • Hydrophilic- coated versions may be available.
  • Graduated sets support progressive dilation.
Vaginal Dilators & Sets

Vaginal Dilators & Sets

Reference set formats 3-, 5- and 6-size graduated sets
Reference materials Medical-grade silicone or smooth medical-grade polymer
Zirve portfolio target 3–30 Fr equivalent sizing where applicable; 5–500 cm

Purpose / Clinical Use

Graduated vaginal dilator sets are used for progressive vaginal dilation in clinical and post- procedural settings. External product references describe smooth, graduated dilators supplied as multi- size sets.

Key Features

  • Graduated sizes support progressive dilation.
  • Smooth, rounded profiles are commonly used for controlled insertion.
  • Medical- grade polymer or silicone configurations are available in external references.
  • Set sizes and dimensions should be selected according to the intended clinical application.
Balloon Dilator

Balloon Dilator

Configurations 5 Fr × 70 cm with 0.035 in guidewire; 6 Fr × 70 cm with 0.038 in guidewire
Balloon concept Predetermined diameter under controlled pressure
Zirve portfolio target 3–30 Fr; 5–500 cm, with balloon diameter/pressure separately validated
Variants Ureteral and other anatomical applications require separate product-specific validation

Purpose / Clinical Use

Balloon dilators provide controlled radial expansion of a target passage. The supplied specifically describes a ureteral balloon dilator for ureteral strictures, stone management and ureteroscopy.

Key Features

  • Dual- lumen catheter with non- compliant distal balloon in the supplied.
  • Controlled inflation pressure up to 20 ATM in the supplied configuration.
  • Kink- resistant shaft and tapered distal end.
  • Radiopaque marker bands for fluoroscopic positioning.
  • Hydrophilic coating for smooth insertion.
Dilator with Peel-Away Sheath

Dilator with Peel-Away Sheath

Reference example Peel-away introducer with 9, 10 or 12 Fr dilator; 37 cm dilator / 32 cm sheath
Zirve portfolio target 3–30 Fr; 5–500 cm
Set concept Dilator + peel-away sheath; guidewire and accessories may be added where specified

Purpose / Clinical Use

A peel- away introducer combines an inner dilator with an outer sheath that can be separated and removed after catheter or instrument placement. Configuration for establishing a conduit during endoscopic urological procedures.

Key Features

  • Inner tapered dilator supports tract establishment.
  • Peel- away sheath separates after placement to avoid disturbing the indwelling device.
  • Radiopaque sheath configurations are used in some systems.
  • Sterile single- use configurations are common in the referenced devices.
Tracheostomy Rhino Dilators

Tracheostomy Rhino Dilators

Reference Blue Rhino-type dilator 38 Fr outer diameter; 20 cm length
Reference loading dilators 21–28 Fr; 20 cm length
Zirve portfolio target 3–30 Fr; 5–500 cm
Application Percutaneous tracheostomy / stoma dilation

Purpose / Clinical Use

Rhino- type tracheostomy dilators are used over a guidewire to enlarge the tracheal stoma during percutaneous tracheostomy procedures. Single- step tapered dilators and loading dilators for tracheostomy tube placement.

Key Features

  • Tapered geometry supports progressive stomal dilation.
  • Guidewire- based use is described in percutaneous tracheostomy techniques.
  • Hydrophilic distal coating is used in some reference devices.
  • Depth markings can assist positioning in certain configurations.